RdF

  • RdF

RdF 20100 Series

  • Butt bonded foil thermocouple
  • Micro-foil® thickness of 0.0128mm (0.0005″)
  • Insulation resistance of 50MΩ at 50VDC in Ungrounded junction TCs
  • 2 wire configuration
  • Removable Kapton® frame for bare foil applications
  • Standard lead length of 6″, additional lengths available on request
  • RdF

RdF 20101 Series

  • Butt bonded foil thermocouple
  • Micro-foil® thickness of 0.0128mm (0.0005″)
  • Insulation resistance of 50MΩ at 50VDC in Ungrounded junction TCs
  • 2 wire configuration
  • Removable Kapton® frame for bare foil applications
  • Standard lead length of 6″, additional lengths available on request
  • RdF

RdF 20102 Series

  • Butt bonded foil thermocouple
  • Micro-foil® thickness of 0.0128mm (0.0005″)
  • Insulation resistance of 50MΩ at 50VDC in Ungrounded junction TCs
  • 2 wire configuration
  • Removable Kapton® frame for bare foil applications
  • Standard lead length of 6″, additional lengths available on request
  • RdF

RdF 22810 Series

  • Polyimide insulated flexible RTD Stikon® temperature sensor
  • Standard sensing element is platinum with a resistance of 100Ω at 0°C
  • 3 or 4 conductor ribbon cable
  • Customisible cable lengths
  • RdF

RdF 26721 Series

  • Stikon® type E thermocouple
  • Insulation resistance of 50MΩ minimum at 50VDC in Ungrounded junction TCs
  • 2 wire configuration
  • Kapton® case material
  • Embeded in a paper thin laminate
  • RdF

RdF 26722 Series

  • Stikon® type E thermocouple
  • Insulation resistance of 50MΩ minimum at 50VDC in Ungrounded junction TCs
  • 2 wire configuration
  • Kapton® case material
  • Embeded in a paper thin laminate
  • RdF

RdF 26723 Series

  • Stikon® type K thermocouple
  • Insulation resistance of 50MΩ minimum at 50VDC in Ungrounded junction TCs
  • 2 wire configuration
  • Kapton® case material
  • Embeded in a paper thin laminate
  • RdF

RdF 26724 Series

  • Stikon® type J thermocouple
  • Insulation resistance of 50MΩ minimum at 50VDC in Ungrounded junction TCs
  • 2 wire configuration
  • Kapton® case material
  • Embeded in a paper thin laminate
  • RdF

RdF 29230 Series

  • Surface platinum RTD temperature sensor
  • Temperature range -200°C to +260°C
  • Time constant of <0.3s on metal surfaces
  • 100 ±0.12Ω or 1000 ±1.2Ω at 0°C (International Class B)
  • Long term stability <0.05°C per 5 years
  • 2 or 3 wire configuration options available
  • RdF

RdF 29309 Series

  • Surface platinum RTD temperature sensor
  • Temperature range -200°C to +260°C
  • Time constant of <0.3s on metal surfaces
  • 100 ±0.12Ω or 1000 ±1.2Ω at 0°C (International Class B)
  • Long term stability <0.05°C per 5 years
  • 4 Wire configuration

RdF 20100 Series

  • Butt bonded foil thermocouple
  • Micro-foil® thickness of 0.0128mm (0.0005″)
  • Insulation resistance of 50MΩ at 50VDC in Ungrounded junction TCs
  • 2 wire configuration
  • Removable Kapton® frame for bare foil applications
  • Standard lead length of 6″, additional lengths available on request

RdF 20101 Series

  • Butt bonded foil thermocouple
  • Micro-foil® thickness of 0.0128mm (0.0005″)
  • Insulation resistance of 50MΩ at 50VDC in Ungrounded junction TCs
  • 2 wire configuration
  • Removable Kapton® frame for bare foil applications
  • Standard lead length of 6″, additional lengths available on request

RdF 20102 Series

  • Butt bonded foil thermocouple
  • Micro-foil® thickness of 0.0128mm (0.0005″)
  • Insulation resistance of 50MΩ at 50VDC in Ungrounded junction TCs
  • 2 wire configuration
  • Removable Kapton® frame for bare foil applications
  • Standard lead length of 6″, additional lengths available on request

RdF 22810 Series

  • Polyimide insulated flexible RTD Stikon® temperature sensor
  • Standard sensing element is platinum with a resistance of 100Ω at 0°C
  • 3 or 4 conductor ribbon cable
  • Customisible cable lengths

RdF 26721 Series

  • Stikon® type E thermocouple
  • Insulation resistance of 50MΩ minimum at 50VDC in Ungrounded junction TCs
  • 2 wire configuration
  • Kapton® case material
  • Embeded in a paper thin laminate

RdF 26722 Series

  • Stikon® type E thermocouple
  • Insulation resistance of 50MΩ minimum at 50VDC in Ungrounded junction TCs
  • 2 wire configuration
  • Kapton® case material
  • Embeded in a paper thin laminate

RdF 26723 Series

  • Stikon® type K thermocouple
  • Insulation resistance of 50MΩ minimum at 50VDC in Ungrounded junction TCs
  • 2 wire configuration
  • Kapton® case material
  • Embeded in a paper thin laminate

RdF 26724 Series

  • Stikon® type J thermocouple
  • Insulation resistance of 50MΩ minimum at 50VDC in Ungrounded junction TCs
  • 2 wire configuration
  • Kapton® case material
  • Embeded in a paper thin laminate

RdF 29230 Series

  • Surface platinum RTD temperature sensor
  • Temperature range -200°C to +260°C
  • Time constant of <0.3s on metal surfaces
  • 100 ±0.12Ω or 1000 ±1.2Ω at 0°C (International Class B)
  • Long term stability <0.05°C per 5 years
  • 2 or 3 wire configuration options available

RdF 29309 Series

  • Surface platinum RTD temperature sensor
  • Temperature range -200°C to +260°C
  • Time constant of <0.3s on metal surfaces
  • 100 ±0.12Ω or 1000 ±1.2Ω at 0°C (International Class B)
  • Long term stability <0.05°C per 5 years
  • 4 Wire configuration

About RdF

RdF is the world’s leading innovator in the design, development and production of surface, insertion and immersion temperature and heat flow sensors including RTD’s, thermocouples and heat flux sensors. Every product in this catalogue is the class leader in ease-of-use, toughness and long-term reliability, all at low cost.

Our multi-market innovations are especially important as applied in demanding aerospace and military applications. Most of the newest surface and immersion temperature sensors in use were introduced, engineered and manufactured by RdF.

RdF operates company-wide under contemporary design, manufacturing and quality systems. RdF is certified to AS9100 and ISO 9001. For their official website, please visit www.rdfcorp.com