Custom Product series

Supporting Manufacturer Information


  • Core Sensors
  • Steel mill pressure transducer
  • Pressures up to 350 Bar
  • Accuracy down to โ‰คยฑ0.25% BFSL
  • Pressure cycles of >100 million
  • Burst pressure of 10X or 20,000 PSI (whichever is less)
  • IP69 protection against high pressure washdown
  • Integral snubber protects against pressure transients
  • Core Sensors
  • Industrial pressure transducer
  • Pressure ranges from vacuum up to 45,000 PSI
  • Accuracy down to โ‰ค ยฑ0.25% BFSL
  • Stability (1 year) of โ‰ค ยฑ0.25% of FS
  • Overpressure of 2x minimum
  • Temperature range from -40ยฐC to +85ยฐC
  • Media Temperature from -40ยฐC to +120ยฐC
  • Core Sensors
  • Compact media isolated pressure sensor
  • Pressure ranges from 0-2 up to 2,000 PSI
  • Accuracy as low as โ‰ค ยฑ0.25% BFSL
  • Stability of โ‰ค ยฑ0.2% of FS (1 year)
  • Pressure cycles of 10 million
  • Overpressure of 2x minimum
  • Burst pressure of 5x or 4,000 PSI
  • Core Sensors
  • Submersible pressure transducer
  • Pressure ranges from 1 to 100 PSI
  • Accuracy down to โ‰คยฑ0.25% BFSL
  • Stability (1 year) of โ‰คยฑ0.25% of FS
  • Pressure cycles of 50 million
  • Overpressure of 2x minimum
  • Burst pressure of 5x or 500 PSI
  • Core Sensors
  • Wet/wet differential pressure transducer
  • Differential pressure ranges up to 300 PSI
  • Line pressure up to 500 PSI
  • Accuracy of โ‰คยฑ0.25% BFSL at 25ยฐC
  • Stability of โ‰คยฑ0.25% of FS
  • Pressure cycles of 4 million
  • Overpressure of 2x or 500 PSI
  • Core Sensors
  • Non-Clogging submersible pressure transducer
  • Pressure ranges from 2 PSI to 50 PSI
  • Flush diaphragm prevents clogging
  • Hastelloy C276 diaphragm material
  • IP68 rated
  • Operating temperature of -40 to +85ยฐC
  • Compensated temperatures from 0 to +55ยฐC
  • Core Sensors
  • Non-incendive pressure transducer
  • Pressure ranges from 50 PSI to 30,000 PSI
  • Accuracy of โ‰คยฑ0.25% BFSL at 25ยฐC
  • Stability of โ‰คยฑ0.25% of FS
  • Pressure cycles of 100 million
  • Overpressure of 2x minimum
  • Burst pressure of 5x or 60,000 PSI
  • Core Sensors
  • Non-incendive low pressure transducer
  • Pressure ranges from 1 PSI up to 49 PSI
  • Temperature range from โˆ’20ยฐC up to +80ยฐC *
  • Accuracy of โ‰คยฑ0.25% BFSL at 25ยฐC **
  • Stability of โ‰คยฑ0.25% of FS (1 year)
  • Pressure cycles of 100 million
  • Overpressure of 2x minimum
  • Core Sensors
  • Non-Incendive Differential Pressure Transducer
  • Differential pressure up to 50 PSI
  • Line pressure up to 500 PSI
  • Accuracy of โ‰คยฑ0.25% BFSL / โ‰คยฑ0.5% BFSL (2 PSI & below)
  • Overpressure of 2X or 500 PSI (whichever is less)
  • Temperature range โˆ’40ยฐC to +80ยฐC
  • Media temperature of -40 to +125ยฐC
  • Core Sensors
  • Explosion-Proof Pressure Transducer
  • Pressure ranges from 50 PSI to 30,000 PSI
  • One piece diaphragm design – No internal O-rings or welds
  • Factory sealed stainless steel case – Withstands harsh environments
  • Accuracy of โ‰คยฑ0.25% BFSL at 25ยฐC (<10,000 PSI)
  • Pressure cycles of 100 million
  • Overpressure of 2x minimum
  • Core Sensors
  • Intrinsically safe pressure transducer
  • Pressure ranges available from 50 PSI up to 30,000 PSI
  • Temperature range โˆ’40ยฐC to +85ยฐC
  • Accuracy of โ‰ค ยฑ0.25% BFSL
  • Burst pressure of 5x or 60,000 PSI whichever is less
  • Stability (1 year) of โ‰ค ยฑ0.25% of FS
  • Pressure cycles of 100 million
  • Core Sensors
  • Intrinsically safe low pressure transducer
  • Pressure ranges from 1 PSI to 49 PSI
  • Accuracy of โ‰คยฑ0.25% BFSL
  • Stability of โ‰คยฑ0.25% of FS (1 year)
  • Pressure cycles of 100 million
  • Overpressure of 2x minimum
  • Burst pressure of 5x or 245 PSI
  • Core Sensors
  • Intrinsically safe submersible pressure transducer
  • Pressure ranges from 1 PSI up to 50 PSI
  • Accuracy of โ‰คยฑ0.25% BFSL
  • Stability of โ‰คยฑ0.25% of FS (1 year)
  • Pressure cycles of 50 million
  • Overpressure of 2x minimum
  • Burst pressure of 5x or 250 PSI
  • Core Sensors
  • Intrinsically safe differential pressure transducer
  • Differential pressure up to 50 PSI
  • Maximum line pressure of 500 PSI
  • Bi-directional pressure ranges
  • Accuracy of โ‰คยฑ0.25% BFSL
  • Stability of โ‰คยฑ0.25% of FS
  • Pressure cycles of 4 million
  • Paine
  • Differential pressure transducer
  • Very low thermal sensitivity shift of ยฑ0.01% of F.S. perยฐC
  • Small, lightweight manifold style mounting for easy installation
  • Temperature compensated design provides highly accurate pressure measurements
  • Shock and vibration resistant design offers highly accurate and reliable pressure monitoring in many operating conditions
  • Durable solution withstands harsh environments for long-lasting performance
  • Custom electrical connection and pressure port adaptors are available on request
  • Paine
  • Differential pressure transducer
  • Thermal sensitivity shift of ยฑ0.01% of F.S. per ยฐC
  • Small, lightweight manifold style mounting for easy installation
  • Shock and vibration resistant design offers highly accurate and reliable pressure monitoring in many operating conditions
  • Compact design for an easy-to-use differential measurement solution
  • Durable solution withstands harsh environments for long-lasting performance
  • Custom electrical connection and pressure port adaptors are available on request