The CS80 intrinsically safe pressure transducer from Core Sensors is a high-strength sensor designed for use in class I, division 1 intrinsically safe environments. Available with pressure ranges from 50 PSI up to 30,000 PSI with an all welded stainless steel construction and customisable configurations. The CS80 offers a choice of electrical outputs and various wetted materials. This sensor series has an operating temperature range of -40°C to +80°C with an accuracy of ≤±0.25% BFSL.
The CS80 Intrinsically Safe Pressure Transducer is certified by CSA to operate safely in Class I, Division 1 Intrinsically Safe rated locations when used with an approved current limiting barrier. The CS80 features a configurable design, allowing Core Sensors to tailor the transducer to your applications operating requirements. The CS80 is offered in a low power configuration, capable of operating from an unregulated power supply of 3-5VDC and consuming 3mA or less of current.
- Intrinsically safe pressure transducer
- Pressure ranges available from 50 PSI up to 30,000 PSI
- Accuracy of ≤±0.25% BFSL (≤±0.5% BFSL >10,000 PSI)
- Stability of ≤±0.25% of FS (1 year)
- Pressure cycles of 100 million
- Overpressure of 2x minimum
- Burst pressure of 5x or 60,000 PSI (whichever is less)
- Electrical output options of 4-20mA, 1-5V, 1-6V, 10mV/V, 0.5-4.5V ratiometric or 0.5-2.5V non-ratiometric
- Temperature range of −40°C to +80°C
- Media temperature range of -40°C to +125°C
- Reverse polarity and EMI protection
- Wetted materials available in 17-4ph, 316L SS, Hastelloy C276 * or Inconel 718 *
- All welded stainless steel construction for a minimum IP65 rating ***
- Semi custom and custom designs available
* Special order item
** IP Rating applies when the electrical connector is attached with the appropriate ingress protection and is dependent on the electrical termination selected. Contact us for more information.
Approvals for the Core CS80 series include:
- CSA Class I, division 1, groups C, D T4
- Class I, zone 0 AEx ia IIB T4 Ga (Ex ia IIB T4 Ga)
- ANSI/UL 122701 single seal
- ABS (American bureau of shipping)
- CE
Typical applications for the CS80 intrinsically safe pressure transducer series include:
- Natural gas compression
- Oil exploration
- Process control
For details on the entity parameters of this part, please see page 4 of the datasheet linked above.
Performance, Thermal, Environmental & Physical Specifications Table
Attribute | Value |
---|---|
Accuracy at 25°C * | ≤±0.25% BFSL ≤±0.5% BFSL (>10,000 PSI) |
Stability (1 Year) | ≤±0.25% of FS |
Pressure Cycles | 100 million |
Overpressure | 2x minimum |
Burst Pressure | 5x or 60,000 PSI (whichever is less) |
Operating Temperature | -40°C to +80°C -20°C to +80°C for DIN 43650-A |
Media Temperature | -40°C to +125°C -40°C to +105°C for DIN 43650-A |
Compensated Temperature | 0°C to +55°C |
Storage Temperature | -40°C to +125°C |
TC Zero | ≤±1% of FS |
TC Span | ≤±1% of FS |
EMI / RFI Protection | Yes |
IP Rating ** | IP65 minimum |
Vibration | 10g, 20 to 2000Hz |
Shock | 100g, 11msec, 1/2 sine |
Electrical Specifications (Current)
Attribute | Value |
---|---|
Outputs | 4 to 20mA |
Excitation | 10 to 28VDC |
Current Consumption | 20mA (typical) |
Output Load | 0 to 800Ω at 10 to 28VDC |
Frequency Response | ~250Hz (minimum) |
Zero Offset (of FS) | ≤±0.5% (typical) ±1% maximum |
Span Tolerance (of FS) | ≤±0.5% (typical) ±1% maximum |
Electrical Specifications (Voltage)
Attribute | Value |
---|---|
Outputs | 1 to 5V 1 to 6V |
Excitation | 10 to 28VDC |
Current Consumption | <10mA |
Output Load | 5kΩ (minimum) |
Frequency Response | ~1kHz (minimum) |
Zero Offset (of FS) | ≤±0.5% (typical) ±1% maximum |
Span Tolerance (of FS) | ≤±0.5% (typical) ±1% maximum |
Electrical Specifications (Ratiometric Voltage)
Attribute | Value |
---|---|
Outputs | 0.5 to 4.5V ratiometric |
Excitation | 5VDC ±0.5V |
Current Consumption | <10mA |
Output Load | 5kΩ (minimum) |
Frequency Response | ~1kHz (minimum) |
Zero Offset (of FS) | ≤±0.5% (typical) ±1% maximum |
Span Tolerance (of FS) | ≤±0.5% (typical) ±1% maximum |
Electrical Specifications (Low Power Voltage)
Attribute | Value |
---|---|
Outputs | 0.5 to 2.5V non-ratiometric |
Excitation | 3 to 5VDC unregulated |
Current Consumption | ≤3mA |
Output Load | 5kΩ (minimum) |
Frequency Response | ~1kHz (minimum) |
Zero Offset (of FS) | ≤±0.5% (typical) ±1% maximum |
Span Tolerance (of FS) | ≤±0.5% (typical) ±1% maximum |
Electrical Specifications (Millivolt)
Attribute | Value |
---|---|
Outputs | 10mV/V |
Excitation | 5VDC (typical) |
Current Consumption | <5mA |
Output Impedance | >1MΩ |
Frequency Response | ~5kHz (minimum) |
Zero Offset (of FS) | ≤±2% (maximum) |
Span Tolerance (of FS) | ≤±2% (maximum) |
Image | Text |
---|---|
Caution must be taken when installing and operating the CS80, CS81, CS82 and CS84 in known Class I, Division 1, Groups A,B,C,D hazardous locations. Any misuse or improper installation may impair the equipment’s intended use and/or protection ratings. Thoroughly read and understand the operating instructions prior to installation. Call us on +44 (0) 1342 330 470 if you are unsure about any of the precautions or instructions or require other details on this or any other core sensor components. |
Core Sensors design and manufacture high-quality sensors for measuring pressure and temperature properties for industrial and hazardous applications worldwide. Core offers solutions for industrial, submersible, differential and hazardous applications in both standard and custom packaging. In-house design and manufacturing capabilities along with strategic manufacturing partners allow Core to create solutions to some of the most complex sensor requirements. Please visit https://core-sensors.com for more information.